Special Fans
We can manufacture our fans in special executions to suit the process including: fan sizes, special finishes, arrangements, sound proofing, insulation and more.
View Product on Company Website
Other Products and Services from Ferrari Fan Technology UK Ltd
Smoke Extract
Ferrari offer a range in both centrifugal and axial fans. Ferrari have the approvals and can supply a wide range of fans for smoke extraction in fire applications where safe evacuation of personnel is required.
FR range centrifugal fans are certified 400 degrees C for two hours (F400)
SR range of centrifugal fans are certified 600 degrees C for two hours (F600)
EF range of axial fans are certified 400 degrees C for two hours (F400)
SF range of axial fans are certified 600 degrees C for two hours (F600).
Ferrari also offer jet fans for the extraction of smoke.
Jet fans can be supplied for tunnel and car park extraction systems. We offer fans with uni-directional as well as reversible functionality.
These fans are certified to EN12101-3 rated F300 (300 degrees C for two hours) or F400 (400 degrees C for two hours)
There are 12 sizes in the range from 315mm to 1250mm diameter impellers. We will undertake Computational Fluid Dynamic (CFD) ananlysis if required. We offer complete package of products including control system (links fans, sensors, warning devices with fire alarm system) CO sensors, accousitc warning sounders and warning lights.
FR range centrifugal fans are certified 400 degrees C for two hours (F400)
SR range of centrifugal fans are certified 600 degrees C for two hours (F600)
EF range of axial fans are certified 400 degrees C for two hours (F400)
SF range of axial fans are certified 600 degrees C for two hours (F600).
Ferrari also offer jet fans for the extraction of smoke.
Jet fans can be supplied for tunnel and car park extraction systems. We offer fans with uni-directional as well as reversible functionality.
These fans are certified to EN12101-3 rated F300 (300 degrees C for two hours) or F400 (400 degrees C for two hours)
There are 12 sizes in the range from 315mm to 1250mm diameter impellers. We will undertake Computational Fluid Dynamic (CFD) ananlysis if required. We offer complete package of products including control system (links fans, sensors, warning devices with fire alarm system) CO sensors, accousitc warning sounders and warning lights.
ATEX Fans
Ferrari have a selection of centrifugal, axial and roof fans that can be manufactured with special anti-sparking materials which are ATEX certified.
Ferrari have the approvals and can supply these fans for both gas and dust explosive atmospheres. The products can be supplied for equipment group II, equipment group 2 and 3, zones 1 and 2 (gas) and zones 21 and 22 (dust).
The application reference standards are as follows (NON-EXHASTIVE LIST):
Directive 2014/34/EU ATEX Directive
Directive 99/9/EC Minimum requirements for improving the safety and health protection of workers potentially at risk from explosive atmospheres.
UNI EN 14986 Design of fans working in potentially explosive atmospheres.
UNI EN 1127-1 Explosive atmospheres - explosion provention and protection - basic concepts and methodology.
UNI EN 13643-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirments.
UNI EN 13643-5 Non- electrical equipment intended for the use in potentially explosive atmospheres - Part 5: Protection by constructional safety "c".
VDMA 24167 Ventilatoren: Sicherheitsanforderungen (Fans: Safety requirements).
EUROVENT 1/5-99 Specification for fan construction and the use to reduce the ignition risk in potentially explosive atmospheres.
IEC/CEI EN 60079 Electrical apparatus for explosive gas atmospheres - Part 0: Equiment general requirments; Part 20-1: Material characteristics for gas and vapour classification - Test methods and data; Part 10: Classification of areas; Part 14: Electrical installations in hazardous areas with combustible gasses (other than mines).
CEI EN 61241-10 Classification of areas where combusible dusts are or may be present.
Ferrari have the approvals and can supply these fans for both gas and dust explosive atmospheres. The products can be supplied for equipment group II, equipment group 2 and 3, zones 1 and 2 (gas) and zones 21 and 22 (dust).
The application reference standards are as follows (NON-EXHASTIVE LIST):
Directive 2014/34/EU ATEX Directive
Directive 99/9/EC Minimum requirements for improving the safety and health protection of workers potentially at risk from explosive atmospheres.
UNI EN 14986 Design of fans working in potentially explosive atmospheres.
UNI EN 1127-1 Explosive atmospheres - explosion provention and protection - basic concepts and methodology.
UNI EN 13643-1 Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirments.
UNI EN 13643-5 Non- electrical equipment intended for the use in potentially explosive atmospheres - Part 5: Protection by constructional safety "c".
VDMA 24167 Ventilatoren: Sicherheitsanforderungen (Fans: Safety requirements).
EUROVENT 1/5-99 Specification for fan construction and the use to reduce the ignition risk in potentially explosive atmospheres.
IEC/CEI EN 60079 Electrical apparatus for explosive gas atmospheres - Part 0: Equiment general requirments; Part 20-1: Material characteristics for gas and vapour classification - Test methods and data; Part 10: Classification of areas; Part 14: Electrical installations in hazardous areas with combustible gasses (other than mines).
CEI EN 61241-10 Classification of areas where combusible dusts are or may be present.
Medium Pressure Centrifugal Fans
Single Inlet Single Width (SISW) and Double Inlet Double Width (DIDW) centrifugal fans in direct or belt driven arrangements with forward curved or backward curved impellers.
8 impeller designs
Airflow volumes up to 200m3/s (720,000m3/h)
'Gas tight' versions for aggressive environments
Temperartures up to 4500C are possible
Temperatures as low as -600C in our ARCTIC range
Variety of finishes include painted mild steel, hot dipped galvanised and 2 grades of stainless steel
8 impeller designs
Airflow volumes up to 200m3/s (720,000m3/h)
'Gas tight' versions for aggressive environments
Temperartures up to 4500C are possible
Temperatures as low as -600C in our ARCTIC range
Variety of finishes include painted mild steel, hot dipped galvanised and 2 grades of stainless steel
Ferrari Fan Technology UK Ltd
PO Box 265, Herne Bay, Kent, CT6 9AZ, United Kingdom
Ferrari Fan Technology UK Ltd based in Herne Bay, are Air movement and ventilation specialists supplying a vast choice of fans to a wide range of industries including Recycling, Pharmaceutical, Paper, Glass and power distribution. We manufacture axial, centrifugal high pressure, medium pressure and low pressure fans. Fans are available in belt drive or direct drive arrangements, we specialise in products for harsh environments with ATEX certification and Smoke extract certification.