Dry Riser Installation
Each dry riser can be no more than 45 metres apart or 60 metres if your building has sprinklers installed. If your building currently has a sprinkler system you still require a dry or wet riser. The inlet breaching valves should be no more than 18 metres from closest fire brigade access point with the closest outlet no more than 45 metres from closest fire brigade access point (where the fire brigade would park their appliance in a emergency).
When it comes to the installation of Dry riser systems it isn’t always necessary to core holes through a slab, we have in the past installed on the external of a building, this pipework doesn’t need to be boxed in and can simply be painted whatever colour required.
Dry Riser Maintenance
It is estimated that over 50% of all Dry Riser Systems in England and Wales are currently not being maintained in accordance with current BS 9990-2015 standards. All Dry Riser systems should be pressure tested to 12 bar of water for a minimum of 15 minutes once a year. Or after use by the fire brigade. The system should be checked for any vandalism that might effect its operation in the event of an emergency.
FIRETECH DRY RISERS have quickly gained a reputation for their knowledge and expertise when it comes to maintaining dry riser systems. We currently work for a number of councils within the London area, as well as housing associations and other fire protection companies across the country which is steadily increasing month on month due to our passion for excellence, we currently service in excess of 50 dry riser systems per week.
Fire Hydrant Testing
They are generally found on large premises such as universities, hospitals and large industrial areas. It is vital to keep these systems in good working order should they ever be needed.
It is advised that you regularly check these and have them tested each year in accordance with the British Standards, as fire hydrants are below ground level they often become clogged, damaged or inaccessible.
Hose Reel Testing
The British Standards require you have a flow rate and pressure test, with a service label attached to the reel, as well as a pressure test on the hose itself every 5 years.
Although hose reels are not as common anymore and some Fire authorities have advised them to be removed and replaced with a alternative means of fighting a fire, whether this be a dry riser, fire extinguisher or sprinkler system, in some cases this isn’t feasible.
FireTech have a wealth of experience within this sector, servicing numerous sites across the country from a large caravan site in Blackpool to a office block in Cornwall, no matter the size of your property we can be off assistance.
On successful maintenance completion of your hose reels you will be issued with certification for each individual hose reel stating they are in good working order, and can be used in the event of a fire. If your systems fail we carry a large stock and can usually solve any issues on the spot.
We also offer decommissioning services, if your hose reel system is no longer required for whatever reason we can safely isolate and remove and cap of the incoming water supply.
Automatic Fire Suppression Units
Fire Tech Dry Risers Ltd is a trusted provider of Automatic Fire Suppression Units, offering vital fire safety equipment designed to detect and suppress fires automatically. With a steadfast commitment to safety and protection, we specialise in supplying high-quality Automatic Fire Suppression Units that are crucial for safeguarding homes, businesses, and industrial environments. Our team's extensive expertise ensures that each unit we provide adheres to stringent safety standards and is equipped with cutting-edge technology to respond swiftly to fire incidents. Whether it's for kitchens, data centers, or manufacturing facilities, Fire Tech Dry Risers Ltd offers a comprehensive range of Automatic Fire Suppression Units tailored to diverse applications. Our dedication to fire safety and our well-established reputation for excellence make us the preferred choice for those seeking dependable automatic fire suppression solutions.
CO2 Fire Extinguishers
Fire Tech Dry Risers Ltd is a trusted supplier of CO2 Fire Extinguishers, offering essential fire safety equipment designed to combat fires involving electrical equipment and flammable liquids. With a strong commitment to safety and preparedness, we specialise in providing high-quality CO2 Fire Extinguishers that are effective and safe for use on Class B and Class E fires. Our team's extensive expertise ensures that every fire extinguisher we supply adheres to stringent safety standards and is ready for quick action in the event of a fire emergency. Whether it's for offices, server rooms, or laboratories, Fire Tech Dry Risers Ltd offers a comprehensive selection of CO2 Fire Extinguishers suitable for a wide range of applications. Our dedication to fire safety and our well-established reputation for excellence make us the preferred choice for those seeking dependable fire extinguisher solutions for specific fire risks.
Multi-Chemical Foam Fire Extinguishers
Water Fire Extinguishers
Wet Chemical Fire Extinguishers
2-Way Inlet Breaching Valve
The bodies are manufactured from spheroidal graphite iron and all fittings are in gunmetal making these inlet breechings extremely durable.
The 2-way dry riser inlet breeching has 65mm Instantaneous male non return valve inlets, suitable for 4-inch pipework. Comes with 1-inch gate.
4 Way Dry Riser Inlet Cabinet
Designed to fit recessed on the external of a building. Comes with pre-drilled holes for ease of installation, signage, and Georgian wired glass front. These cabinets are designed to be fitted before the Inlet Breaching valve.
Size- 595 high x 595mm wide x 295 depth.
Technical Specification
– Made from 16swg Zintec steel
– 38mm boarder
– Yale slam lock (with key)
– Stainless steel hinge
– Conforms to BS5041
4-Way Inlet Breaching Valve
The bodies are manufactured from spheroidal graphite iron and all fittings are in gunmetal making these inlet breechings extremely durable.
The 4-way dry riser inlet breeching has 65mm Instantaneous male non return valve inlets, suitable for 6-inch pipework. Comes with 1-inch gate.
Anti-Vandal Dry Riser Inlet Architrave
Fully protective cabinet for environments prone to Vandalism. Design to sit fully over existing recessed cabinets. Comes with predrilled holes for ease of installation.
Technical Specification
– Made from 16swg Zintec steel
– Stainless steel hinge
– Conforms to BS5041
– FB Padlock and key included
Automatic Air Release Valve
Made from brass and is designed to go at the highest point of a Dry riser system to expel the air out of the system. With 1-inch male thread.
Female 65mm Threaded Landing Valve
Made in gunmetal to be fitted to a building dry riser system, designed, and constructed in accordance with BS5041 part 2.
The materials the valves are constructed from are all corrosion resistant, tough and durable. This ensures long life plus efficient service when needed, can used with lock nuts to avoid theft.
• Manufactured in accordance with BS5041 part1
• Suitable for onshore and offshore
• Tested to 16.5 bars and 22.5 bars
• Low Maintenance
• Compact and elegant design
Floor Mounted Dry Riser Inlet Cabinet
Design to sit within walkways when a building does not Allow for standard recessed or surface mounted cabinets. Advise should be sought of building control or your local fire authority before installation. These cabinets can fit directly over the valve.
Technical Specification
– Made from 16swg Zintec steel
– 5mm chequred plate electro plated silver door
– 595mm wide x 395mm length x 295mm depth
Horizontal Dry Riser Inlet Cabinet
Design to fit recessed on the external of a building. Comes with pre-drilled holes for ease of installation, signage, and Georgian wired glass front. These cabinets are designed to be fitted before the Inlet Breaching valve.
Size- 395mm high x 595mm high x 295mm depth
– Made from 16swg Zintec steel
– 38mm boarder
– Yale slam lock (with key)
– Stainless steel hinge
– Conforms to BS5041
Male 65mm Threaded Landing Valve
Made in gunmetal to be fitted to a building dry riser system, designed, and constructed in accordance with BS5041 part 2.
The materials the valves are constructed from are all corrosion resistant, tough and durable. This ensures long life plus efficient service when needed, can used with lock nuts to avoid theft.
• Manufactured in accordance with BS5041 part1
• Suitable for onshore and offshore
• Tested to 16.5 bars and 22.5 bars
• Low Maintenance
• Compact and elegant design
PN16 65mm Dry Riser Gate Valve Flanged
Made in gunmetal to be fitted to a building dry riser system, designed, and constructed in accordance with BS5041 part 2.
The materials the valves are constructed from are all corrosion resistant, tough and durable. This ensures long life plus efficient service when needed, can used with lock nuts to avoid theft.
- Manufactured in accordance with BS5041 part1
- Suitable for onshore and offshore
- Tested to 16.5 bars and 22.5 bars
- Low Maintenance
- Compact and elegant design
- Corrosion resistant
Right Angled Landing Valve – Pn16
Generally used when space is at a premium and standard landing valves cannot be used.
• Manufactured in accordance with BS5041 part1
• Suitable for onshore and offshore
• Tested to 16.5 bars and 22.5 bars
• Low Maintenance
• Compact and elegant design
• Corrosion resistant
Rigid Case Fire Blanket BS Kitemarked
- Slimline design making them ideal for small areas and kitchens.
- Fire Blanket is manufactured from woven twill cloth.
- Supplied in compact plastic cases with holes on the rear for easy wall mounting.
- Opening at bottom of case allows blanket to be easily pulled out
- Red durable single-piece molded design.
- Kitemark certified to BSEN1869, TUV certified to EN1869 for use in Europe.
- K40 Blanket – weaved twill cloth.
- Large label design.
Soft Pack Fire Blanket BS Kitemarked
- Ideal for smothering and extinguishing fires in homes, kitchens and schools.
- K40 Blanket – Fire blanket is manufactured from woven twill cloth.
- Kitemark certified to BSEN1869:1997 TUV certified to EN1869 for use in Europe.
- Held by a Velcro strap which is released when pulled.
- Reliable and easy to operate.
- Red screen-printed soft PVC pack.
Vertical Inlet Cabinet- Stainless Steel
This stainless steel cabinet comes with pre Drilled holes for ease of installation, with silver finish to give your building a cleaner, upmarket look.
Dimensions 395 high x 595 width x295mm depth
Technical Specification
– Made from 16swg Zintec steel
– Yale slam lock (with key)
– Stainless steel hinge
– Conforms to BS5041
Automatic Dry Powder Suppression Unit 1Kg
ABC Dry Powder Automatic fire Suppression Units are commonly used to protect machinery/plant and where there is a risk of fire such as in boat/vehicle engine compartments. Our 1kg Dry Powder Automatic fire Suppression Unit is compact and economical, They are safe for us on electrical equipment.
Automatic Dry Powder Suppression Unit 2Kg
ABC Dry Powder Automatic fire Suppression Units are commonly used to protect machinery/plant and where there is a risk of fire such as in boat/vehicle engine compartments. Our 2kg Dry Powder Automatic fire Suppression Unit is compact and economical, They are safe for us on electrical equipment.
About us
Established in 2017, Fire Tech Dry Risers Ltd initially began as a subcontractor focused solely on providing labour services. Prior to this venture, we gained over a decade of valuable industry experience while working with a prominent national dry riser company.
Building a stellar reputation, our director, Jack Maher, made a significant move by acquiring a van and initiating subcontracting services under the banner JM Fire Protection. We experienced rapid growth, expanding both our team and client portfolio, and soon had four operational vans. This allowed us to collaborate with numerous fire protection companies on projects of varying scales across the United Kingdom. Chances are, we've likely handled dry riser installations for you on previous projects.
Our Products & Services Include:
Dry Riser Installation
Dry risers can have diverse configurations, yet typically, they are mandated for structures surpassing 18 meters in height or when the fire brigade's access is significantly limited.
Dry Riser Maintenance
Maintaining your dry riser in proper working condition is of utmost importance. It is strongly advised to conduct a visual inspection every six months and a hydraulic test every twelve months on your system. Neglecting the maintenance of your building's dry riser (or other fire protection equipment) may potentially invalidate your building insurance coverage.
Fire Hydrant Testing
Regularly inspecting your fire hydrants and conducting annual tests following British Standards recommendations is recommended. Fire hydrants, being situated underground, can frequently experience issues such as blockages, damage, or inaccessibility.
Hose Reel Testing
The maintenance of hose reels is regulated by BS-EN-671-3, which advises regular checks and inspections by a qualified individual or company. According to British Standards, it is necessary to conduct a flow rate and pressure test, affix a service label to the reel, and perform a pressure test on the hose itself every 5 years.
Other Fire Suppression Equipment on Offer Includes:
- Dry Riser Cabinets
- Dry Riser Valves
- Fire Blankets
- Fire Extinguishers
- Automatic Suppression Units
We firmly hold the belief that this foundation provides us with a strong footing to advance and elevate our company to the next stage, which is why we have rebranded as FireTech Dry Risers Ltd. Our primary focus now revolves around providing comprehensive services encompassing the design, supply, installation, and maintenance of dry risers. As a family-operated business, backed by years of hands-on experience and accumulated expertise, we are confident in our ability to deliver an unparalleled level of service within the industry.
We can adapt our services to align with your specific requirements and are open to working on a labour-only basis as needed. None of our vans display signage, so if discretion is essential on your sites, we are more than willing to accommodate your project needs. As an independent fire protection company, we offer highly competitive pricing. Our clientele spans a wide spectrum, including M&E companies, councils, and housing associations.
Images
Reviews
Trade Associations