SAX-D Area Alarm

SAX-D Area Alarm

The SAX-D Area Alarm is a digitally controlled medical gas monitoring system, expertly designed to provide clear and high-visibility monitoring for up to six independent piped medical gases downstream of the final AVSU.

  • Monitors up to six gases using 4–20mA pressure or vacuum transducers
  • Individual 1.7” OLED display for each gas
  • High- and low-pressure alarm indication
  • Pressure drop early warning indication
  • Comprehensive system fault monitoring (data, wiring, and mains failure)
  • Fail-safe common fault relay output
  • Temporary mute feature with a 15-minute automatic re-sound
  • Engineer lockout facility for maintenance periods
  • Bluetooth configuration interface (for engineer use only)
  • Modbus and SAX Bus interface capability
  • Fully compliant with HTM 02-01 standards
SAX-6 Area Alarm

SAX-6 Area Alarm

The SAX-6 Area Alarm is a digitally controlled medical gas monitoring system engineered to deliver precise and reliable monitoring of pipeline pressures within clinical settings.

  • Monitors up to 6 gases using pressure switches
  • Continuous real-time digital pressure monitoring
  • High- and low-pressure alarm indications (low pressure only for vacuum)
  • Clear LED backlit digital display
  • Individual gas identification windows for easy recognition
  • Audible and visual alarm notifications
  • Alarm mute function with automatic reset capability
  • Internal system fault monitoring for enhanced safety
  • Modular PCB design for straightforward servicing
  • Fully compliant with HTM 02-01 regulations
SA-6 Area Alarm

SA-6 Area Alarm

The SA-6 Area Alarm is a reliable, robust, and straightforward medical gas monitoring system, meticulously engineered for enduring performance and easy installation.

  • Monitors high and low pipeline pressure (low pressure monitoring available only for vacuum systems)
  • Cable integrity monitoring between pressure switches and the alarm panel
  • Compatible with termination boards or direct connections
  • Configurable for operation with or without termination boards
  • Master–Repeater capability (supports up to 2 Repeater panels)
  • Fully compliant with HTM 02-01 standards
  • Backwards PCB compatibility across all product generations
  • Designed for extended service life and straightforward maintenance
SDX-15 Plant Alarm

SDX-15 Plant Alarm

The SDX-15 Medical Gas Alarm system is a multiplexed solution that utilises the MEDCON data transmission standard, employing a pulse width modulated signal over 2 core inter-panel wiring. It is capable of displaying up to 15 services, each containing up to 4 conditions in addition to a normal state.

Each service can be divided into four individual displays, enabling signals—such as the common alarm output from area alarms—to be relayed to a central point or any location where this information is necessary. Signals from plant machinery or other monitored equipment are transmitted to the system via transmitters strategically located near the equipment. A complete service can be relayed from a single transmitter, or, if needed (such as in the case of remote plant EMS), services can be transmitted from multiple transmitters. The services are displayed at each panel as required, with a rotary switch for selecting each service within the panel. Five long-life 10 x 20 mm block LEDs per service indicate the service conditions through a replaceable lens situated behind a wipe-clean membrane.

When an alarm condition arises, the corresponding alarm indicator will flash, and the audible alarm will sound if activated by a 4-way DIL switch located on the panel for that specific service. Engaging the Mute switch on a repeater panel will silence the alarm on that panel. Similarly, operating the Mute switch on the central panel will silence the alarm from the central unit and change the flashing alerts to a steady light on all panels (the audible alert on repeaters will remain unaffected). If the alarm condition persists, the audible alert will reactivate, necessitating a repeat of the mute action. In scenarios where an alarm condition must be sustained for an extended duration, such as during pipeline maintenance, the re-trigger can be halted by silencing the audible with the Lockout button within the panel. The audible alert will not reactivate for that specific condition of service until it has returned to normal, and then re-entered an alarm state. A volume control is conveniently located within the panel. A loudspeaker is used for the audible alert instead of a buzzer, providing a softer tone that effectively draws attention to the alarm while being tolerable for staff engaged in other tasks. Remote audible and muting units are also available for use in areas where full display is unnecessary or where access to the panel is impractical.

Plant to Alarm

Plant to Alarm

The Plant To Alarm links to the SDX-15 Alarm system via 2-core data bus cable. The Transmitter accepts 4no input signals, wired from a single gas, via a 5-core cable (4no switched conditions and 1no Common). The input signals are typically monitored for integrity via an end-of-line termination board (known as a TB4 PCB).

Medcon RTX1

Medcon RTX1

The RTX1-SDX transmitter offers a reliable connection to the SDX-15 Alarm system through a robust 2-core data bus cable.


This transmitter is designed to be mounted directly within or adjacent to the gas source for optimal performance.


It features 4 input signals that are wired directly from the plant or manifold, employing failsafe logic—where an open contact indicates a fault (i.e. NO line monitoring on TB4 PCBs).


Input connections consist of a 5-core cable, accommodating 4 switched conditions along with 1 common line.

Internal ITX

Internal ITX

The SDX-ITX transmitter is situated within an SDX-15 Plant Alarm, positioned close to the gases being monitored for optimal accuracy.


Four input signals are connected from each gas source (either plant or manifold) using an end-of-line termination board, referred to as a TB4 PCB.


Each gas requires up to a 5-core cable (four switched conditions and one common), allowing for the integration of up to four gases through a single SDX-ITX transmitter.

Remote RTX

Remote RTX

The SDX-RTX transmitter connects seamlessly to the SDX-15 Alarm system using a 2-core data bus cable.


Four input signals can be wired from each gas source (either plant or manifold) through an end-of-line termination board, referred to as a TB4 PCB (optional).


Each gas necessitates a cable with up to five cores (four for switched conditions and one for Common), allowing for a maximum of four gases to be inputted through a single SDX-RTX unit.

AGSS - Duplex

AGSS - Duplex

Shire Controls Limited provides an extensive selection of Duplex AGSS (Anaesthetic Gas Scavenging Systems) that adhere to the HTM02-01 standard. Our systems are engineered to deliver optimal safety and performance, with flow rates varying from 300 l/m to 2900 l/m at the source, offering flexible solutions suitable for medical facilities of all sizes.

Our AGSS Plants are produced under a BS EN 13485-certified Quality Management System, guaranteeing compliance with rigorous standards for medical devices. These systems are essential in protecting healthcare professionals by effectively extracting exhaled gases from operating theatres and safely venting them outside the hospital, thus minimising long-term exposure to potentially hazardous substances.

AGSS - Simplex

AGSS - Simplex

Shire Controls Limited provides an extensive selection of Simplex AGSS (Anaesthetic Gas Scavenging Systems). Our systems are designed to ensure maximum safety and performance, with flow rates available from 300 l/m to 1600 l/m at source, offering adaptable solutions suitable for medical facilities of all sizes.

Our AGSS Plants are produced in accordance with a BS EN 13485-certified Quality Management System, guaranteeing compliance with rigorous standards for medical devices. These systems are essential for protecting healthcare professionals by efficiently extracting exhaled gases from operating rooms and releasing them safely outside the hospital, thus minimising long-term exposure to potentially dangerous substances.

About us

Shire Controls Ltd is a trusted UK manufacturer of medical gas alarm systems, established in 1980. With over 40 years of experience, we design and produce reliable alarm solutions that play a vital role in hospital Medical Gas Pipeline Systems (MGPS).

Our medical gas alarm systems continuously monitor local pipeline pressures (area alarms) as well as gas source plant and manifold status (plant alarms) across healthcare facilities, helping to ensure the safe and uninterrupted supply of medical gases essential for patient care.

Reliability and availability are central to our work. Shire Controls has established a strong reputation for producing robust, dependable products, supported by responsive, customer-focused service and quick turnaround times throughout the product lifecycle.

Our Products Include:

Area Alarms

Our area alarms are commonly used in medical and laboratory settings to monitor gas levels and alert users to potential hazards, helping ensure compliance with safety standards. Known for their precision, durability, and ease of use, we support our clients with high-quality products and technical expertise to help maintain safe and controlled working environments.

Plant Alarms

Our solutions help protect critical plant equipment by detecting faults, unsafe conditions, or system failures before they escalate into costly downtime or safety risks. Built for accuracy, durability, and ease of integration, our plant alarms support continuous operations across a wide range of sectors, helping ensure safety, compliance, and efficient performance.

AGSS

Our AGSS solutions are engineered for reliable performance, efficient gas capture, and compliance with relevant healthcare safety standards. Suitable for hospitals, theatres, and dental facilities, they support a safer working environment by reducing exposure to harmful gases and maintaining high levels of air quality and operational safety.

In 1990, we broadened our range to include Anaesthetic Gas Scavenging Systems (AGSS) in both Simplex and Duplex formats. Built on proven design principles, these systems offer reliable performance and are designed for straightforward servicing and long-term support.

Our products are engineered for long-term maintainability. New generations of Medical Gas Alarms and AGSS are fully compatible with existing systems, allowing current components, including control PCBs, to be integrated into older installations. This enables customers to upgrade, expand, or adapt their systems as needed, without the cost of full replacement.

All Shire Controls medical devices are UKCA and CE approved and fully compliant with HTM 02-01 standards. Our alarm systems also use volt-free, fail-safe interfaces, making them easily adaptable for non-medical and industrial applications where dependable monitoring and alarm signalling are required.